The Planarcell allows direct mounting of a platter etc. in
low profile, high-accuracy platform scales. Four Planarcells are located at the corners
of a weigh platform that can be any size and shape. Different capacities
allow a single set of components to be used in a family of scale
platforms of many sizes and capacities. The Planarcell has overload
protection built in and can be used with confidence in applications
where dropped items and other abuse is present.
FEATURES
Capacity range 7.5 to 150 kg
Fully overload protected
Higher accuracy than single point load
cells
High stiffness gives fast response
Less than 2” high, allowing low profile platform construction
IP65 protection
1000 ohm impedance reduces electrical load and self-heating
Allows wide range of platform sizes
Different platter mounts available to allow secured or drop-on
platters
Accurately matched output allows total interchangeability and
replacement without calibration
4-3/4"x 2-3/4"x 1.64" overall height with
load button shown
Rated capacity:
7.5, 37.5, 50, 75 or 150kg.Contact us for other capacities
OIML accuracy class:
C3, 3000 divisions.C4, 4000 divisions available
Corner balance:
Current and voltage matched to within ±0.1%.
Output:
1.00 mV/V at full capacity.
Excitation, Zero balance:
5 – 15 volts,
zero balance
±0.1
mV/V
Creep error, 30 min:
±0.024% of
applied
load
Zero return error, 30 min:
±0.0167% of applied load
Temperature span error:
±0.001% of applied load / ºC
Temperature zero error:
±0.00186% of rated output / ºC
Output impedance:
1000 ± 10 ohm
Input impedance:
1160 ± 10 ohm
Temperature range:
Operating -10 to +40
ºC. Storage -30 to
+70 ºC
Safe vertical overload:
300 kg static or dynamic shock load
Safe side overload:
200 % of rated capacity
Sensing element:
Vishay 380 planar beam, or equal
Environmental protection:
IP65.Dust
cover optional
Note: Although the Planarcell’s accuracy meets all legal
requirements for 3000 divisions, this scale has not yet been NTEP or
Canadian Weights and Measures approved. If required, contact us
regarding this subject. 
The Planarcell can be used in groups of two, three or four in
conjunction with the R1930 transmitter or any digital load cell
indicator.
CUSTOM APPLICATIONS
We welcome your custom application. Depending on volume, we can
design suitable mountings, with or without our patented overload
protection, to suit your application. Contact us to discuss your
needs.
Quick Information
Request, direct to our sales staff. We pledge to respond by next
business day. Details will not be divulged to outsiders and will only be
used to respond to your request.
Contact us directly at:
U.S. / Canada 6428 Trans-Canada Highway, St Laurent,
QC,
H4T 1X4, Canada. Phone: +1 514 940 0337
or toll free: 1 800 632 7083
Fax: +1 514 940 0342
Latin America and
Caribbean
(sales, information, Espanõl)
Bank of America City Centre
401 E. Las Boulevard - Suite 130
Ft. Lauderdale FL 33301
Phone: +1 954 828 9316
Fax: +1 954 522 2170
Copyright 2000-2012 Scale-Tron Inc.